Instruction Manual
Model 1029C
Control Concepts
Power Control System
Another quality product from:
7128 Shady Oak Road
Eden Prairie, MN 55344 USA
(952) 949-9009 Fax (952) 949-9559
www.researchinc.com
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Power Control System

Instruction Manual Model 1029C Control Concepts Power Control System Another quality prod

Page 2 - CONCEPTS

MODEL 1029C 6 10/19/2007INSTALLATION DRAWINGS (Continued)10.85LINELOAD DANGERHIGH VOLTAGESHORTEDSCROVERC

Page 3

MODEL 1029C 7 10/19/200726.125.05.007.60.332 Dia. (4)DANGERHIGH VOLTAGESHORTEDSCROVERCURRENTCOMMANDLOADINDICATORINDICATORCWWRUN (+) C

Page 4 - MODEL 1027 TABLE OF CONTENTS

MODEL 1029C 8 10/19/2007COMMAND CONNECTIONS123456789101112131415161718OVER CURRENT TRIPRESET SWITCHTO ALARM ORPOWER DISCONNECTCIRCUIT

Page 5 - FEATURES

MODEL 1029C 9 10/19/2007COMMAND CONNECTIONS (Continued)CWWRUN (+) COM(-) CCWIDLE (+) WSHORTEDSCRRELAYOVERCURRENTRELAYFB. BK.COMMON RE

Page 6 - SPECIFICATIONS

MODEL 1029C 10 10/19/2007COMMAND CONNECTIONS (Continued)CWWRUN (+) COM(-) CCWIDLE (+) WSHORTEDSCRRELAYOVERCURRENTRELAYFB. BK.COMMON R

Page 7 - SPECIFICATIONS (Continued)

MODEL 1029C 11 10/19/2007COMMAND CONNECTIONS (Continued)CWWRUN (+) COM(-) CCWIDLE (+) WSHORTEDSCRRELAYOVERCURRENTRELAYFB. BK.COMMON R

Page 8 - INSTALLATION

MODEL 1029C 12 10/19/2007POWER CONNECTIONSLINE 2LINE 1VOLTAGESUPPLYLOADLINE 1LINE 2LOAD 1GNDFigure 15. Power Connections.LINE 2LINE

Page 9 - INSTALLATION DRAWINGS

MODEL 1029C 13 10/19/2007FEEDBACK SELECTIONConnector P2 on the circuit board allows the selection of feedback type. (See Figure 18).T

Page 10 - HIGH VOLTAGE

MODEL 1029C 14 10/19/2007ADJUSTMENTSThe I Span and V Span pots (and PowerSpan and Power Zero pots, when factoryinstalled), are sealed

Page 11 - 0.332 Dia. (4)

MODEL 1029C 15 10/19/2007ADJUSTMENTS (Continued)XXXXInstalledfor powerfeedbackonlyRun Span Pot.Run Zero Pot.Idle Span Pot.Idle Zero P

Page 12 - COMMAND CONNECTIONS

CONTROLCONCEPTSINC.INSTALLATION MANUALMODEL 1029C7870 PARK DRIVECHANHASSEN, MN 55317(952) 474-62001-800-765-2799FAX (952) 474-6070www.ccipower.com

Page 13

MODEL 1029C 16 10/19/2007TROUBLESHOOTINGCAUTION: HIGH VOLTAGES ARE PRESENT ON THIS CONTROLLER AND ON PORTIONS OF THE PRINTED CIRCUIT

Page 14

MODEL 1029C 17 10/19/2007REPLACEMENT PARTSSCHEMATIC DWG: CCI No. D1000954AITS RECOMMENDED THAT THE CONTROLLER AND LOADBE PROTECTED B

Page 15

MODEL 1029C 18 10/19/2007MODEL NUMBER IDENTIFICATION1029C-[X]-[XXX]V-[XXX]A-IL[XXX]-R[XXX]-I[XXX]1029C The basic model number. [X]

Page 16 - POWER CONNECTIONS

MODEL 1029C 19 10/19/2007WARNING: the Control Concepts, Inc, model 1029C power controller uses power thyristors to switch voltage to

Page 17 - FEEDBACK SELECTION

CONTROL CONCEPTS, INC. 2 YEAR LIMITED WARRANTYCONTROL CONCEPTS, INC. warrants that the products delivered will be as described in the sales order or c

Page 18 - ADJUSTMENTS

MODEL 1027 TABLE OF CONTENTSDESCRIPTION 1FEATURES 1SPECIFICATIONS 2INSTALLATION 4INSTALLATION DRAWINGS 5COMMAND CONNECTIONS 8POWER CONNECTIONS

Page 19 - ADJUSTMENTS (Continued)

MODEL 1029C 1 10/19/2007DESCRIPTIONMODEL COVERED:This manual describes the Control Concepts model 1029C controller with the following

Page 20 - MANUFACTURED BY

MODEL 1029C 2 10/19/2007SPECIFICATIONSThe following specifications apply over an ambient temperature of 0 to 55ºC and a supply voltag

Page 21 - REPLACEMENT PARTS

MODEL 1029C 3 10/19/2007SPECIFICATIONS (Continued)ZERO AND SPAN: Potentiometers on the circuit board allow zero and span adjustments

Page 22 - MODEL NUMBER IDENTIFICATION

MODEL 1029C 4 10/19/2007INSTALLATIONTRANSFORMER TAP:Open lid and locate power transformer. Check voltage tap is on desired line volt

Page 23 - THEORY OF OPERATION

MODEL 1029C 5 10/19/2007INSTALLATION DRAWINGS7.656.650.501.12510.610.08.270.600.288 X 0.50 (2)0.29 (2)10.6LOADLINE 1LINE 2GROUNDFigur