Precision-control-systems 3629C Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
MODEL 3629C 11 04/10/2007
COMMAND CONNECTIONS
COMMON (-)
VOLTAGE OR
CURRENT
COMMAND SIGNAL
POSITIVE (+)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Figure 12. Voltage or current command connections.
CCW
CW
WIPER
I K
POT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Figure 13. Potentiometer command connections.
The Controller Ready signal is controlled by an open
collector transistor which goes low with respect to Pin 12
when the controller is in the ready state.
Any of the following conditions will prevent the controller
from entering the ready state.
Over current.
One or more of the line phases is not present.
One or more phases are not present on the firing circuit
board. (Circuit fuse may be cleared.)
The phase lock is not enabled.
The gate drive is not enabled.
The Over Current Trip reset switch may be closed.
READY
5 V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Figure 14. Ready Output.