Vue de la page 13
10
As shown in Figure 4-4, the junction box is designed to accept wiring from the removable
heater cable as well as wiring from the electrical power source. Different wiring configurations
are shown so that the heater wiring can be correctly connected within the junction box
corresponding to a particular (supply) line voltage, i.e. since the Model 5209-05, 5209-10 and
5209-16 models use T3 lamps rated for 240-volt operation, one could install the heater wiring
so that either 240-volt single- or three-phase supply power could be used.
Heater Thermostat
As stated above, a heater safety thermostat is mounted to the back of the model 5209 reflector
and wired into the 19-pin connector mounted to the heater cover. Wiring for the thermostat is
also integrated within the removable electrical heater cable.
When wired into an appropriately designed power source (i.e. the Model 915 ControlIR Power
Control System – See Appendix for detail), the normally closed thermostat will open upon
reaching an overheat condition (160°F) resulting in an alarm condition to occur at the power
controller. The thermostat will close once the heater cools down to a safe operating
temperature (approximately 140°F).
An alarm condition signal can be configured within the power control system to alert the user
that the alarm condition exists (i.e. signal light, signal horn, etc.). Additionally, the power
Figure 4-3